Study of Water Impinging Jet Cooling Mechanism for Hot Rolled Wire Rod
by See, Seong-Kyu
Publisher - POSCO, Pohang, Korea
Category - General Novel
Pre-cooling system used in the cooling process of the hot rolled wire rod is a system that sprays cooling water at high pressure to cool the fast-moving wire rod to a required tempera ture when the rod passes through the cooling nozzle of the cooling box. The influence of the flow phenomenon of this cooling nozzle affecting the rod temperature and the factors affect ing the cooling efficiency were examined through experiments and numerical analysis. The confined-type cooling nozzle showed a phenomenon where secondary flow or vortex was produced on the flow depending on the existence of chambers and variations in the Reynolds number, and the production of such vortex affected the rod cooling efficiency phenomenon. The wire rod cooling efficiency can be said to be most effective at a point where the wire rod and water jet impinge due to flow increase, viz, the Reynolds number increase. It is believed that the optimal conditions featuring excellent cooling efficiency can be deduced in the future by analyzing the flow conditions and design conditions.
Please login to borrow the book.